60W UPS Backup Battery Power Supply for Emergency Use

Origin:
Zhejiang, China
Brand:
ZTAO
Series Name:
SC
Output Power:
60W
DC Output Voltage:
CH1:13.8V, CH1: 13.4V (charging), CH1:27.6V, CH2: 26.5V (charging)
Input Voltage:
90~264VAC, 127~370VDC
Working Frequency:
50~60HZ
Working Temperature:
-20℃ ~ +65℃
Product Dimensions:
129 * 98 * 38 mm (L * W * H)
Certifications:
CE FCC ROHS
Warranty:
3 Years

60W Backup Battery Uninterruptible Power Supplies UPS Batteries Home Backup for Server Computer Data Center Emergency Use

Description

The SC-60-XX series is a 60W (UPS) chassis-type industrial power supply with charging function. The output voltage includes 12V/24V, etc., and there is also a charging output. It has a small rated current to provide backup power for safe access to system needs. It can be adapted to different load application requirements to meet the needs of most industrial applications. Self-cooling heat dissipation and all-round protection ensure the reliability and stability of this series of products.

Features

  • Internationally Universal Full-Range AC Input
  • Protection Types: Short Circuit / Overload
  • Natural Air Cooling
  • Features Power-On / Charging / AC Power In dicator (LED)
  • 100% Full Load Burn-in Test
  • Battery Low Voltage Protection
  • 3-Year Warranty

Application

Industrial Control, Mechanical Electrical Equipment, Electronic Instruments, Industrial Automation, Electronic Equipment, Semiconductor Equipment, etc. (excluding information technology equipment)

Model Specification

MODEL SC-60-12 SC-60-24
OUTPUT DC Voltage CH1:13.8V CH1:13.4V(charging) CH1:27.6V CH2:26.5V(charging)
Rated Current 4.0A 0.35A 2.0A 0.25A
Current range 0~4.0A - 0~2.0A -
Rated power 59.9W 61.8W
Ripple&noise 100mVp-p - 100mVp-p -
Voltage 11.3~14.9V - 21.3~29.8V -
INPUT Voltage range 90~264VAC 127~370VDC
Efficiency 81% 83%
SAFETY Withstand voltage Input to Output: 1.5KVAC; Input to Ground: 1.5KVAC; Output to Ground: 500VAC
Insulation resistance Input to Output, Input to Ground, Output to Ground: 100 Ohms/500VDC/25℃/70%RH
OTHERS Dimension 129*98*38mm(L*W*H)
Packing 0.52kg/45pcs/24Kg/0.034m³

Mechanical Specification and Installation(mm)

60W UPS Backup Battery Power Supply for Emergency Use

60W UPS Backup Battery Power Supply for Emergency Use

TB1 Terminal Pin No.Assignment

Pin No. Assignment
1 AC/L
2 AC/N
3 FG⏚

CN1 External Indicator Light Description

Indicator color Description
Green DC OUTPUT Indicator light
Red AC INPUT Indicator light
white Battery charging indicator light

The ST cold start function, switch allows the UPS to be started directly with batteries in the absence of mains power, meeting the user's emergency needs

Pin Function    
L AC LINE screw: M4*9.5  Torque: 22Kgf.cn (2.2N.m) 8-M3 mounting holes for customer system  Mounting screw: M3  Installation torque: 8 kgf·cm (0.8 N·m)  The screw should extend no more than 3 mm into the enclosure.  Remark:  Unit: mm [inch]; unspecified tolerances are ±0.5 [±0.020]
N AC NETURAL
⏚ EARTH
-Vo DC output - screws: M4*9.5 Torque: 22Kgf.cn (2.2N.m)
+Vo DC output +

Characteristic Curve

Input voltage VS Output load

60W UPS Backup Battery Power Supply for Emergency Use

AMBIENT TEMPERATURE VS Input voltage VS Output load Output Load

60W UPS Backup Battery Power Supply for Emergency Use

Notes:

1.For more detailed test data, please contact our technical support to obtain the application notes for the corresponding product.

2.This product is suitable for use in natural air convection environments. For use in enclosed environments, please contact our technical support.

Application Industries

60W UPS Backup Battery Power Supply for Emergency Use

Industrial Automation and Production Lines

Provides stable DC power for PLCs, relays, sensors, small actuators, HMI modules and control circuits used in automated production equipment. It is suited to compact machine builders and production lines that require reliable low-voltage power.

60W UPS Backup Battery Power Supply for Emergency Use

Indoor LED Displays and Signage

Supports receiver cards, control boards and LED modules used in indoor video walls, menu boards and advertising displays. Select the correct output voltage and reserve sufficient capacity for LED startup current.

60W UPS Backup Battery Power Supply for Emergency Use

Security, CCTV and Access Control

Supports CCTV recorders, access controllers, door-lock relays and alarm interfaces used in commercial entrance and surveillance systems. Install the power supply inside suitable protected equipment.

60W UPS Backup Battery Power Supply for Emergency Use

Self-Service Kiosks and Ticketing Equipment

A practical power source for controllers, payment modules, sensors, small motors and internal lighting in vending machines, ticketing kiosks and other indoor self-service equipment.

FAQ

Q:What output voltages are available for the SC-60?

A:The supplied specification lists 12V and 24V versions.

Q:Does the SC-60 accept worldwide AC input?

A:Yes. The input range is 90~264 VAC, 50-60 Hz, or 127–370 VDC.

Q:How do I choose the correct version?

A:Confirm the load voltage first, then calculate continuous current and total power. Include headroom for startup surge, cable loss, elevated ambient temperature and future expansion.

Q:Can the output voltage be adjusted?

A:Yes. The supplied specification lists an adjustable DC output range of ±10%. Keep the adjusted voltage within the limits of the connected equipment.

Q:Is the SC-60 fanless?

A:Yes. The SC-60 uses natural air convection. Keep all ventilation openings unobstructed.

Q:Can the SC-60 be used outdoors?

A:Not as an exposed unit. The ventilated metal enclosure is not waterproof. Install it indoors or inside a suitable protected enclosure.

Q:What protection functions are included?

A:The supplied specification lists overload, over-current and short-circuit protection.

Q:What is the operating temperature?

A:The supplied specification lists -20°C to +65°C. Derating and adequate airflow may be required at elevated temperatures.

Q:What are the dimensions and weight?

A:The SC-60 measures 129 x 98 x 38 mm and weighs approximately 0.52kg/45pcs/24Kg/0.034m³.

Q:What information is required for a quotation?

A:Provide output voltage, continuous and peak current, AC input voltage, quantity, installation environment, cooling conditions and any certification or labeling requirements.