HDR-100-XX series products for a 100W self-cooling rail industrial power supply, the whole series of products with a wide voltage AC and DC input, output voltage including 12V/15V/24V36V/48V, etc., can be adapted to meet different load application requirements to meet most of the industrial applications, with good conversion efficiency, compact housing design, good heat dissipation, and all-round protection to ensure the reliability and stability of this series of products.
Industrial control, mechanical and electrical, electronic instruments, industrial automation, electronic equipment, semiconductor equipment, etc. (except information technology equipmen)
| MODEL | HDR-100-12 | HDR-100-12N | HDR-100-15 | HDR-100-15N | HDR-100-24 | HDR-100-24N | HDR-100-36 | HDR-100-36N | HDR-100-48 | HDR-100-48N | |
| OUTPUT | DC Voltage | 12V | 15V | 24V | 36V | 48V | |||||
| Rated Current | 7.1A | 7.5A | 6.13A | 6.5A | 3.83A | 4.2A | 2.6A | 2.7A | 1.92A | 2.1A | |
| Current range | 0~7.1A | 0~7.5A | 0~6.13A | 0~6.5A | 0~3.83A | 0~4.2A | 0~2.6A | 0~2.7A | 0~1.92A | 0~2.1A | |
| Rated power | 85.2W | 90W | 92W | 97.5W | 92W | 100.8W | 93.6W | 100.8W | 92.2W | 100.8W | |
| Ripple&noise | 100mVp-p | 100mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | ||||||
| Voltage | 10.2~13.8V | 13.5~16.5V | 21.6~26.4V | 32.4~39.6V | 43.2~52.8V | ||||||
| INPUT | Voltage range | 88~264VAC 125~370VDC | |||||||||
| Efficiency | 86% | 87% | 88.5% | 88% | 88% | ||||||
| SAFETY | pressure resistance | Input to Output :1.5KVAC | |||||||||
| Insulation impedance | Input to Output :100 Ohms/500VDC/25℃ /70%RH | ||||||||||
| OTHERS | Dimension | 70*90*54.5mm(L*W*H) | |||||||||
| Packing | 0.2kg/pcs | ||||||||||


Terminal Pin No.Assignment
| Pin No. | Pin Function | Pin No. | Pin Function |
| 5,6 | +V | 2 | AC/N |
| 3,4 | -V | 1 | AC/L |
| Pin | Function | ||
| L | AC LINE | screw: M2.5*8.5 Torque: 4Kgf.cn (0.4N.m) | Installation of rail-type customer system Guide rail installation: TS35/7.5 or TS35/15 Note: Unit: mm [inch]; Unmarked tolerance is ±0.5 [±0.020] |
| N | AC NETURAL | ||
| ⏚ | EARTH | ||
| -Vo | DC output - | screws: M2.5*8.5 Torque: 4Kgf.cn (0.4N.m) | |
| +Vo | DC output + |
Input voltage VS Output load

AMBIENT TEMPERATURE VS Input voltage VS Output load Output Load

Notes:
1.If you need to know more detailed test data when applying, please contact our technical support to obtain the application notes for the corresponding products.
2.This product is suitable for use in a natural air convection environment. If it is to be used in a closed environment, please contact our technical support staff.

Industrial Automation and Production Lines
Provides stable DC power for PLCs, relays, sensors, small actuators, HMI modules and control circuits used in automated production equipment. It is suited to compact machine builders and production lines that require reliable low-voltage power.

Indoor LED Displays and Signage
Supports receiver cards, control boards and LED modules used in indoor video walls, menu boards and advertising displays. Select the correct output voltage and reserve sufficient capacity for LED startup current.

Security, CCTV and Access Control
Supports CCTV recorders, access controllers, door-lock relays and alarm interfaces used in commercial entrance and surveillance systems. Install the power supply inside suitable protected equipment.

Self-Service Kiosks and Ticketing Equipment
A practical power source for controllers, payment modules, sensors, small motors and internal lighting in vending machines, ticketing kiosks and other indoor self-service equipment.
Q:What output voltages are available for the HDR-100?
A:The supplied specification lists 12V, 15V, 24V, 36V and 48V versions.
Q:Does the HDR-100 accept worldwide AC input?
A:Yes. The input range is 88~264 VAC, 50-60 Hz, or 125~370 VDC.
Q:How do I choose the correct version?
A:Confirm the load voltage first, then calculate continuous current and total power. Include headroom for startup surge, cable loss, elevated ambient temperature and future expansion.
Q:Can the output voltage be adjusted?
A:Yes. The supplied specification lists an adjustable DC output range of ±10%. Keep the adjusted voltage within the limits of the connected equipment.
Q:Is the HDR-100 fanless?
A:Yes. The HDR-100 uses natural air convection. Keep all ventilation openings unobstructed.
Q:Can the HDR-100 be used outdoors?
A:Not as an exposed unit. The ventilated metal enclosure is not waterproof. Install it indoors or inside a suitable protected enclosure.
Q:What protection functions are included?
A:The supplied specification lists overload, over-current and short-circuit protection.
Q:What is the operating temperature?
A:The supplied specification lists -20°C to +65°C. Derating and adequate airflow may be required at elevated temperatures.
Q:What are the dimensions and weight?
A:The HDR-100 measures 70 x 90 x 54.5 mm and weighs approximately 0.2kg.
Q:What information is required for a quotation?
A:Provide output voltage, continuous and peak current, AC input voltage, quantity, installation environment, cooling conditions and any certification or labeling requirements.