S Single Switch Power Supply

Single Output 60W 12V 5A DC toggle Switching Mode Power Supply

Place of Origin;
Zhejiang, China
Brand Name:
ZTAOJT
Model Number:
S-60-12
Output Type:
Single
Input Voltage:
100~132VAC/185~264VAC 260~370VDC(switch on220VAC)
Output Voltage:
12V/24V/36V/48V can be choose or customized
Output Frequency:
50~60Hz
Output Current:
5A
Output Power
60W
Efficiency:
80%
Workig Temperature:
-10℃~+60℃
Certification:
CE FCC ROHS ISO9001
Test:
100%Full Load Burn-in Test
Protection:
Shortcuit Overtemp Overload overvoltage
Warranty
3 Years
Size
159*98*38mm(L*W*H)
MODEL   S-60-5 S-60-12 S-60-24 S-60-36 S-60-48
OUTPUT DC Voltage 5V 12V 24V 36V 48V
Rated Current 12A 5.0A 2.5A 1.6A 1.25A
Current range 0~12A 0~5.0A 0~2.5A 0-1.6A 0-1.25A
Rated power 60W 60W 60W 59.76W 60W
Ripple&noise(max. 78mVp-p 100mVp-p 100mVp-p 120mVp-p 120mVp-p
Voltage ADJ. range 5~7V 12~14V 24~28V 36~38V 48V~53V
Voltage tolerance ±2.0% ±2.0% ±1.0% ±1.0% ±1.0%
Line regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load regulation ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
Setup,.Rise,Time 200ms,78ms/230VAC  200ms,85ms/115VAC(full load)
Hold up time(typ) 20ms/230VAC  45ms/115VAC(full load)
INPUT Voltage range 100~132VAC/185~264VAC  260~370VDC(switch on220VAC)
Frequency range 50~60Hz
Efficiency(Typ) 76% 80% 82% 82% 84%
AC current(Typ) 1.6A/115VAC  0.8A/230VAC
Inrush current (Typ) Cold start: 20A/115VAC  40A/230VAC
Leakage current <1mA/240VAC
PROTECTION Over load 105%~150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over voltage 8~10V 15~16.5V 29~33V 40~45V 58~65V
Protection mode ,tum off output voltage,restart to recover
Environment Working TEMP -10℃~+60℃
Working humidity 20~65% RH non-condensing
Storage TEMP humidity -10℃~+60℃,10-95%RH
TEMP.coefficient ±0.03%℃(0~50℃)
Vibration 10~500Hz,2G 10min./1cycle,60min each along X,Y,Z axes Install in accordance with IEC60068-2-6
SAFETY Safety regulations UL60950-1. CB(IEC60950-1)In line with the certification
Withstand voltage l/P-O/P:1.5KVAC  I/P-FG:1.5KVA  O/P-FG:0.4KVAC
Insolation resistance I/P-O/P. I/P-FG, O/P-FG:100M Ohms/500VDC
Electromagnetic compatible emission Compliance to  EN55022(CISPR22)CLASS B.EN61000-3-2,-3.
EMC immunity requirements  Compliance to EN61000-4-2,3,4.5,6,8,11. EN55024. EN1000-6-1 Class A light industry standard
OTHERS MTBF ≥370K hrs. MIL-HDBK-217F(25℃)
Dimension 159*98*38mm(L*W*H)
Packing 0.45Kg:30PCS/14Kg/0.9CUFT

Single Output 60W 12V 5A DC toggle Switching Mode Power SupplySingle Output 60W 12V 5A DC toggle Switching Mode Power SupplySingle Output 60W 12V 5A DC toggle Switching Mode Power SupplySingle Output 60W 12V 5A DC toggle Switching Mode Power SupplySingle Output 60W 12V 5A DC toggle Switching Mode Power SupplySingle Output 60W 12V 5A DC toggle Switching Mode Power SupplySingle Output 60W 12V 5A DC toggle Switching Mode Power SupplySingle Output 60W 12V 5A DC toggle Switching Mode Power SupplySingle Output 60W 12V 5A DC toggle Switching Mode Power SupplySingle Output 60W 12V 5A DC toggle Switching Mode Power SupplySingle Output 60W 12V 5A DC toggle Switching Mode Power SupplySingle Output 60W 12V 5A DC toggle Switching Mode Power SupplySingle Output 60W 12V 5A DC toggle Switching Mode Power SupplySingle Output 60W 12V 5A DC toggle Switching Mode Power Supply