MODEL | S-120-5 | S-120-12 | S-120-24 | S-120-36 | S-120-48 | ||
OUTPUT | DC Voltage | 5V | 12V | 24V | 36V | 48V | |
Rated Current | 24A | 10A | 5A | 3.3A | 2.5A | ||
Current range | 0~24A | 0~10A | 0~5A | 0~3.3A | 0~2.5A | ||
Rated power | 120W | 120W | 120W | 118.8W | 120W | ||
Ripple&noise(max.) | 76mVp-p | 120mVp-p | 120mVp-p | 240mVp-p | 240mVp-p | ||
Voltage ADJ. range | 5~7V | 12~14V | 24~28V | 36~38V | 48V~53V | ||
Voltage tolerance | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ||
Line regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||
Load regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||
Setup,Rise,Time | 500ms, 70ms/230VAC 500ms,70ms/115VAC(full load) | ||||||
Hold up time(typ) | 36ms/230VAC 32ms/115VAC(full load) | ||||||
INPUT | Voltage range | 100~132VAC/185~264VAC 260~370VDC(switch on220VAC) | |||||
Frequency range | 50~60Hz | ||||||
Efficiency (Typ) | 80% | 80% | 84% | 84% | 85% | ||
AC current (Typ) | 2.6A/115VAC 1.6A/230VAC | ||||||
Inrush current (Typ) | Cold start:20A/115VAC 40A/230VAC | ||||||
Leakage current | <2.5mA/240VAC | ||||||
PROTECTION | Over load | 105%~150% in rated output power | |||||
Protection type: Hiccup mode,recovers automatically after fault condition is removed | |||||||
Over voltage | 8~10V | 15~16.5V | 29~33V | 40~45V | 58~65V | ||
Protection mode,tum off output voltage, restart to recover | |||||||
Environment | Working TEMP | -10℃~+60℃ | |||||
Working humidity | 20~90% RH non-condensing | ||||||
Storage TEMP humidity | -10℃~+65℃. 10~95% RH | ||||||
TEMP.coefficient | ±0.03%℃(0~50℃) | ||||||
Vibration | 10~500Hz,2G 10min./1cycle,60min each along X,Y,Z axes Install in accordance with IEC60068-2-6 | ||||||
SAFETY | Safety regulations | UL60950-1,TUV EN60950-1,GB4939.1 In line with the certification | |||||
Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVA O/P-FG:0.4KVAC | ||||||
Insolation resistance | l/P-O/P I/P-FG, 0/P-FG: 100M Ohms/500VDC | ||||||
Electromagnetic compatible emission | Compliance to EN55011 ,EN55032(CISPR32)CLASS B,EN61000-3-2,3,EAC TP TC 020 | ||||||
EMC immunity requirements | Compliance to EN61000-4-2,3.4.5.6.8,11. EN55024,EN1000-6-2(EN50082-2), Class A heavy industry standard | ||||||
OTHERS | MTBF | ≥432.1K hrs.MIL-HDBK-217F(25℃) | |||||
Dimension | 199*98*38mm(L*W"H) | ||||||
Packing | 0.7Kg:20PCS/15Kg/0.72CUFT |