SDR-75-XX series products for a 75W rail industrial power supply, the whole series of products with a wide voltage AC and DC input, output voltage including 12V/24V/36 V/48V, etc., can be adapted to different load application requirements to meet the ne eds of most industrial applications, good conversion efficiency, compact housing desi gn, good heat dissipation, as well as a full range of protection, to ensure that this seri e s of products of reliability and stability.
Industrial control, mechanical and electrical, electronic instruments, industrial automation, electronic equipment, semiconductor equipment, etc. (e xcept information technology equipment)
| MODEL | SDR-75-12 | SDR-75-15 | SDR-75-24 | SDR-75-36 | SDR-75-48 | |
| OUTPUT | DC Voltage | 12V | 15V | 24V | 36V | 48V |
| Rated Current | 6.3A | 5A | 3.2A | 2.1A | 1.6A | |
| Current range | 0~6.3A | 0~5A | 0~3.2A | 0~2.1A | 0~1.6A | |
| Rated power | 75.6W | 75W | 76.8W | 75.6W | 76.8W | |
| Ripple&noise | 80mVp-p | 80mVp-p | 100mVp-p | 120mVp-p | 120mVp-p | |
| Voltage | 10.2~13.8V | 13.5~16.5V | 21.6~26.4V | 32.4~39.6V | 43.2~52.8V | |
| INPUT | Voltage range | 90~264VAC 127~370VDC | ||||
| Efficiency | 86% | 86% | 89% | 90% | 90% | |
| SAFETY | pressure resistance | Input to Output :1.5KVAC; Input to Ground :1.5KVAC; Output to Ground :500VAC | ||||
| Insulation impedance | Input to Output, Input to Ground, Output to Ground :100 Ohms/500VDC/25℃ /70%RH | |||||
| OTHERS | Dimension | 32*125.2*102mm(L*W*H) | ||||
| Packing | 0.4kg/pcs | |||||


TB1 Terminal Pin No.Assignment
| Pin No. | Pin Function |
| 1 | FG⏚ |
| 2 | AC/N or DC- |
| 3 | AC/L or DC+ |
TB1 Terminal Pin No.Assignment
| Pin No. | Pin Function |
| 1,2 | DC OUTPUT -V |
| 3,4 | DC OUTPUT +V |
| Pin | Function | ||
| L | AC LINE | screw: M2.5*8.5 Torque: 4Kgf.cn (0.4N.m) | mounting holes for rail-type customer systems Rail mounting: TS35/7.5 or TS35/15 Remarks: Unit: mm [inch]; unlabelled tolerances are ±0.5 [±0.020]. |
| N | AC NETURAL | ||
| ⏚ | EARTH | ||
| -Vo | DC output - | screws: M2.5*8.5 Torque: 4Kgf.cn (0.4N.m) | |
| +Vo | DC output + |
Input voltage VS Output load

AMBIENT TEMPERATURE VS Input voltage VS Output load Output Load

Notes:
1.If you need to know more detailed test data, please contact our technical support to get the application notes of the corresponding products.
2.This product is suitable for use in a natural air convection environment, if used in a closed environment, please contact our technical support staff.

Industrial Automation and Production Lines
Provides stable DC power for PLCs, relays, sensors, small actuators, HMI modules and control circuits used in automated production equipment. It is suited to compact machine builders and production lines that require reliable low-voltage power.

Indoor LED Displays and Signage
Supports receiver cards, control boards and LED modules used in indoor video walls, menu boards and advertising displays. Select the correct output voltage and reserve sufficient capacity for LED startup current.

Security, CCTV and Access Control
Supports CCTV recorders, access controllers, door-lock relays and alarm interfaces used in commercial entrance and surveillance systems. Install the power supply inside suitable protected equipment.

Self-Service Kiosks and Ticketing Equipment
A practical power source for controllers, payment modules, sensors, small motors and internal lighting in vending machines, ticketing kiosks and other indoor self-service equipment.
Q:What output voltages are available for the SDR-75?
A:The supplied specification lists 12V, 15V, 24V, 36V and 48V versions.
Q:Does the SDR-75 accept worldwide AC input?
A:Yes. The input range is 90~264 VAC, 50-60 Hz, or 127~370 VDC.
Q:How do I choose the correct version?
A:Confirm the load voltage first, then calculate continuous current and total power. Include headroom for startup surge, cable loss, elevated ambient temperature and future expansion.
Q:Can the output voltage be adjusted?
A:Yes. The supplied specification lists an adjustable DC output range of ±10%. Keep the adjusted voltage within the limits of the connected equipment.
Q:Is the SDR-75 fanless?
A:Yes. The SDR-75 uses natural air convection. Keep all ventilation openings unobstructed.
Q:Can the SDR-75 be used outdoors?
A:Not as an exposed unit. The ventilated metal enclosure is not waterproof. Install it indoors or inside a suitable protected enclosure.
Q:What protection functions are included?
A:The supplied specification lists overload, over-current and short-circuit protection.
Q:What is the operating temperature?
A:The supplied specification lists -20°C to +65°C. Derating and adequate airflow may be required at elevated temperatures.
Q:What are the dimensions and weight?
A:The SDR-75 measures 32 x 125.2 x 102 mm and weighs approximately 0.4kg.
Q:What information is required for a quotation?
A:Provide output voltage, continuous and peak current, AC input voltage, quantity, installation environment, cooling conditions and any certification or labeling requirements.